TY - JOUR
T1 - Carbon monoxide distributions from the IASI/METOP mission
T2 - Evaluation with other space-borne remote sensors
AU - George, M.
AU - Clerbaux, C.
AU - Hurtmans, D.
AU - Turquety, S.
AU - Coheur, P. F.
AU - Pommier, M.
AU - Hadji-Lazaro, J.
AU - Edwards, D. P.
AU - Worden, H.
AU - Luo, M.
AU - Rinsland, C.
AU - McMillan, W.
PY - 2009
Y1 - 2009
N2 - The Infrared Atmospheric Sounding Interferometer (IASI) onboard the MetOp satellite measures carbon monoxide (CO) on a global scale, twice a day. CO total columns and vertical profiles are retrieved in near real time from the nadir radiance spectra measured by the instrument in the thermal infrared (TIR) spectral range. This paper describes the measurement vertical sensitivity and provides a first assessment of the capabilities of IASI to measure CO distributions. On the global scale, 0.8 to 2.4 independent pieces of information are available for the retrieval. At mid latitudes, the information ranges between 1.5 and 2, which enables the lower and upper troposphere to be distinguished, especially when thermal contrast is significant. Global distributions of column CO are evaluated with correlative observations available from other nadir looking TIR missions currently in operation: the Measurements of Pollution in the Troposphere (MOPITT) onboard TERRA, the Atmospheric Infrared Sounder (AIRS) onboard AQUA and the Tropospheric Emission Spectrometer (TES) onboard AURA. The IASI CO columns are compared with MOPITT, AIRS and TES CO columns, adjusted with the a priori, for three different months: August 2008, November 2008 and February 2009. On average, total column discrepancies of about 7% are found between IASI and the three other sounders in the Northern Hemisphere and in the equatorial region. However when strong CO concentrations are present, such as during fire events, these discrepancies can climb as high as 17%. Instrument specifications of IASI versus other missions are also discussed.
AB - The Infrared Atmospheric Sounding Interferometer (IASI) onboard the MetOp satellite measures carbon monoxide (CO) on a global scale, twice a day. CO total columns and vertical profiles are retrieved in near real time from the nadir radiance spectra measured by the instrument in the thermal infrared (TIR) spectral range. This paper describes the measurement vertical sensitivity and provides a first assessment of the capabilities of IASI to measure CO distributions. On the global scale, 0.8 to 2.4 independent pieces of information are available for the retrieval. At mid latitudes, the information ranges between 1.5 and 2, which enables the lower and upper troposphere to be distinguished, especially when thermal contrast is significant. Global distributions of column CO are evaluated with correlative observations available from other nadir looking TIR missions currently in operation: the Measurements of Pollution in the Troposphere (MOPITT) onboard TERRA, the Atmospheric Infrared Sounder (AIRS) onboard AQUA and the Tropospheric Emission Spectrometer (TES) onboard AURA. The IASI CO columns are compared with MOPITT, AIRS and TES CO columns, adjusted with the a priori, for three different months: August 2008, November 2008 and February 2009. On average, total column discrepancies of about 7% are found between IASI and the three other sounders in the Northern Hemisphere and in the equatorial region. However when strong CO concentrations are present, such as during fire events, these discrepancies can climb as high as 17%. Instrument specifications of IASI versus other missions are also discussed.
UR - https://www.scopus.com/pages/publications/70450259333
U2 - 10.5194/acp-9-8317-2009
DO - 10.5194/acp-9-8317-2009
M3 - Article
AN - SCOPUS:70450259333
SN - 1680-7316
VL - 9
SP - 8317
EP - 8330
JO - Atmospheric Chemistry and Physics
JF - Atmospheric Chemistry and Physics
IS - 21
ER -