Feasibility study of superoxide chemical ionization mass spectrometry (O2− CIMS) for real-time gas-phase measurements of per- and polyfluoroalkyl substances (PFAS)

  • Yufan Hu
  • , Joji W. Sherman
  • , Michael J. Davern
  • , Zane A. Alsebai
  • , Yoonsub Kim
  • , Yue Zhang
  • , Chenyang Bi
  • , Barbara J. Turpin
  • , Jason D. Surratt
  • University of North Carolina at Chapel Hill
  • Department of Environmental Sciences and Engineering
  • Texas A&M University
  • Aerodyne Research, Inc.

Research output: Contribution to journalArticlepeer-review

Abstract

Per- and polyfluoroalkyl substances (PFAS) are highly persistent pollutants with known adverse impacts on environmental and public health. Traditional gas-phase PFAS detection approaches often involve labor-intensive sample collection and preparation, while offering low temporal resolution. Alternatively, chemical ionization mass spectrometry (CIMS) allows for real-time airborne PFAS detection at sub-pptv sensitivity. While reagent ion generation often requires hazardous chemicals (e.g., nitric acid, methyl iodide (I), and acetic anhydride), superoxide (O2) CIMS provides a safer alternative and is better suited for mobile platforms where ventilation, space, and weight are constrained. O2 CIMS has five main reagent ions (i.e., O2, (H2O)O2, CO3, (CO2)O2, and CO2(H2O)O2) and low-background mass spectra above m/z 200. Thus, it is well suited to the relatively high molecular weights of airborne PFAS. Mass calibration was performed with a 5 : 1 fluorotelomer alcohol (FTOH) permeation tube. Ionization was found to occur mainly through deprotonation or adduct formation. Calibrations for fourteen environmentally- and industrially-relevant PFAS compounds are presented, including FTOHs, fluorotelomer diols, fluorinated sulfonamides, epoxides, and glycol ethers. While perfluoroalkyl carboxylic acids (PFCAs) were not detected, O2 CIMS offered higher sensitivity and lower detection/quantification limits than I CIMS for FTOHs; however, it remains a complementary PFAS measurement technique to I CIMS. Moreover, it yielded distinct fingerprint signals for FTOHs, confirming compound identification. This study demonstrates the utility of O2 CIMS for real-time airborne PFAS analysis in commonly encountered environments by capturing 6 : 2 FTOH gaseous emissions from fast-food packaging at room temperature, underscoring its strong promise for future development and applications.

Original languageEnglish
Pages (from-to)3418-3429
Number of pages12
JournalAnalyst
Volume151
Issue number12
DOIs
StatePublished - Jun 15 2026
Externally publishedYes

Fingerprint

Dive into the research topics of 'Feasibility study of superoxide chemical ionization mass spectrometry (O2− CIMS) for real-time gas-phase measurements of per- and polyfluoroalkyl substances (PFAS)'. Together they form a unique fingerprint.

Cite this