The development of a new Kalman-filter time scale at NIST

Jian Yao, Thomas Parker, Judah Levine

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

We report on a preliminary design of a new Kalman-filter Hydrogen-maser time scale at NIST. The time scale is composed of a few Hydrogen masers and a Cs clock. The Cs clock is used as a reference clock, to ease operations with existing data. All the data used in this paper are real measurement data, except mentioned specifically. Unlike most other time scales, this time scale uses three basic time-scale equations, instead of only one equation. Also, this time scale can detect a clock error (i.e., time error, frequency error, or frequency drift error) automatically. A frequency step of 6.8×10-15 s/s (which typically corresponds to - 20C temperature change of a H-maser chamber) in a clock only leads to - 2.5 ns change in the time scale in 100 days, thanks to the advanced error-detection technique. A frequency-drift step of 5.4×10-21 s/s2 in a clock only leads to - 11 ns change in the time scale in 100 days. These features make the new time scale stiff and less likely to be affected by a bad clock. Tests show that the time scale deviates from the UTC by less than ± 5 ns for -100 days, when the time scale is initially aligned to the UTC and then is completely free running. Once the time scale is steered to an external frequency standard (such as a Cs fountain), it can maintain the time with little error even if the external frequency standard stops working for tens of days. At NIST, we have the Cs fountain running in 2015 September (23 days), 2015 December (14 days) and 2016 February (18 days). Although the Cs fountain runs for only 55 days in total, the time scale steered to the Cs fountain has a deviation of less than 4 ns (peak-to-peak) from the UTC, during MJD 57265 - 57500 (235 days). This can be helpful when we do not have a continuously-running fountain, or when the continuously-running fountain accidentally stops, or when optical clocks run occasionally.

Original languageEnglish
Title of host publicationPrecise Time and Time Interval Systems and Applications Meeting, PTTI 2017
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages18-25
Number of pages8
ISBN (Electronic)9781510855397
DOIs
StatePublished - 2017
Externally publishedYes
EventPrecise Time and Time Interval Systems and Applications Meeting, PTTI 2017 - Monterey, United States
Duration: Jan 30 2017Feb 2 2017

Publication series

NameProceedings of the Annual Precise Time and Time Interval Systems and Applications Meeting, PTTI
Volume2017-January
ISSN (Electronic)2333-2085

Conference

ConferencePrecise Time and Time Interval Systems and Applications Meeting, PTTI 2017
Country/TerritoryUnited States
CityMonterey
Period01/30/1702/2/17

Fingerprint

Dive into the research topics of 'The development of a new Kalman-filter time scale at NIST'. Together they form a unique fingerprint.

Cite this