Skip to main navigation Skip to search Skip to main content

Validation of the CrIS fast physical NH3 retrieval with ground-based FTIR

  • Enrico Dammers
  • , Mark W. Shephard
  • , Mathias Palm
  • , Karen Cady-Pereira
  • , Shannon Capps
  • , Erik Lutsch
  • , Kim Strong
  • , James W. Hannigan
  • , Ivan Ortega
  • , Geoffrey C. Toon
  • , Wolfgang Stremme
  • , Michel Grutter
  • , Nicholas Jones
  • , Dan Smale
  • , Jacob Siemons
  • , Kevin Hrpcek
  • , Denis Tremblay
  • , Martijn Schaap
  • , Justus Notholt
  • , Jan Willem Erisman
  • Vrije Universiteit Amsterdam
  • Université Laval and Environment and Climate Change Canada
  • University of Bremen
  • Verisk Atmospheric and Environmental Research
  • University of Colorado Boulder
  • Drexel University College of Engineering
  • University of Toronto
  • Jet Propulsion Laboratory, California Institute of Technology
  • Universidad Nacional Autónoma de México
  • University of Wollongong
  • NIWA
  • University of Wisconsin-Madison
  • Science Data Processing Inc.
  • Netherlands Organisation for Applied Scientific Research
  • Louis Bolk Institute - LBI

Research output: Contribution to journalArticlepeer-review

56 Scopus citations

Abstract

Presented here is the validation of the CrIS (Cross-track Infrared Sounder) fast physical NH3 retrieval (CFPR) column and profile measurements using ground-based Fourier transform infrared (FTIR) observations. We use the total columns and profiles from seven FTIR sites in the Network for the Detection of Atmospheric Composition Change (NDACC) to validate the satellite data products. The overall FTIR and CrIS total columns have a positive correlation of Combining double low line ĝ€0.77 (N =218) with very little bias (a slope of 1.02). Binning the comparisons by total column amounts, for concentrations larger than 1.0 × 1016 molecules cm-2, i.e. ranging from moderate to polluted conditions, the relative difference is on average ∼0 5% with a standard deviation of 25-50%, which is comparable to the estimated retrieval uncertainties in both CrIS and the FTIR. For the smallest total column range (< 1.0 × 1016molecules cm-2) where there are a large number of observations at or near the CrIS noise level (detection limit) the absolute differences between CrIS and the FTIR total columns show a slight positive column bias. The CrIS and FTIR profile comparison differences are mostly within the range of the single-level retrieved profile values from estimated retrieval uncertainties, showing average differences in the range of 20 to 40%. The CrIS retrievals typically show good vertical sensitivity down into the boundary layer which typically peaks at 850hPa (g 1.5km). At this level the median absolute difference is 0.87(std =±0.08)ppb, corresponding to a median relative difference of 39%(std =±2%). Most of the absolute and relative profile comparison differences are in the range of the estimated retrieval uncertainties. At the surface, where CrIS typically has lower sensitivity, it tends to overestimate in low-concentration conditions and underestimate in higher atmospheric concentration conditions.

Original languageEnglish
Pages (from-to)2645-2667
Number of pages23
JournalAtmospheric Measurement Techniques
Volume10
Issue number7
DOIs
StatePublished - Jul 25 2017

Fingerprint

Dive into the research topics of 'Validation of the CrIS fast physical NH3 retrieval with ground-based FTIR'. Together they form a unique fingerprint.

Cite this